GIS mapping softeware GIS GIS mapping mapping softeware GIS softeware this is new replica watches website,We offer our customers swiss replica watches Rolex watches is designed to be solemn, practical,BMR not showy style was by a large number of people love.CHOPARD150 years since, OMEGA Swiss Omega watches put it firmly in the vanguard of the world watch industry location,PRADA BVLGARIremarkable achievements lay.you can but many DEWITT GUCCI HERMES PIAGET watches.replica watchesreplica best watches this is new jordan shoes air jordan shoes website.The Air Jordan 1 was released in 1985 kicking off not only the greatest legacy in sneakers.The air jordan retro 11 are the most famous and most popular model of the Air Jordan line.The Air Jordan shoes 13 (XIII)¡¯s featured a nice hologram on the ankle and the design was inspired by a panther.The air jordan 23 (XV) was released in 1999/2000.cheap jordan shoes Jordans 16 is the first shoe after Michael¡¯s retirement. The design of the Jordan shoes 17 originated from the air craft X-15 The air jordan 10 was released in 2002. Jordans 18 were equipped with a gaiter/shroud that was removable and that would cover almost more than half of the shoe, Air Jordans 19 were no worse. 无标题文档

Name: Din Rail series
Type:
DRT-301C-II


DRT-301C-II  Modbus 
 
 
DRT-301C-II offers all the measurement capabilities required to monitor an electrical. You can monitor all three phases at the same time.

Description:

1. Measuring of Active and reactive energy, accuracy class B&A (CI.1& 2)
2. 7 DIN module
3. 35mm standard DIN rail installation
4. Direct metering up to 100A
5.  Transformer metering for 1,2 or 5A
6. 27 CT Changing-Ratios to choose
7. Large LCD display, Pulse output , IR and RS485 Port
8. Communication baud rate can be set 1200,2400,4800,9600
9.  The protocol is Modbus RTU with 16 bit CRC
 
Specifications:
Electrical characteristics:
Nominal voltage     (Un)                     230/400V AC (3~)
Operational voltage                           161/279  300/520V AC (3~)
Base current (Ib):
        CT type                                          1.5A
        Directly connect                              10A
Maximum rated current (Imax)     
        CT type                                           6A
        Directly connect                              100A                                 
Frequency(Hz)                                       50/60
CT Changing-Ratio                                  27 ratios to choose
Measurement accuracy:
Current and voltage                            0.5% of reading
Power                                              1% of reading
Frequency                                       0.2Hz
Power factor                                    1% of reading
Active energy                                   IEC62052-11,IEC62053-21(CI.1& 2)
Reactive energy                               IEC62053-23
Communication:
 RS485 port                                     2-wire Modbus RTU with 16 bit CRC
 Communication baud rate                       1200,2400,4800,9600