GIS mapping softeware GIS GIS mapping mapping softeware GIS softeware this is new replica watches website,We offer our customers swiss replica watches Rolex watches is designed to be solemn, practical,BMR not showy style was by a large number of people love.CHOPARD150 years since, OMEGA Swiss Omega watches put it firmly in the vanguard of the world watch industry location,PRADA BVLGARIremarkable achievements lay.you can but many DEWITT GUCCI HERMES PIAGET watches.replica watchesreplica best watches this is new jordan shoes air jordan shoes website.The Air Jordan 1 was released in 1985 kicking off not only the greatest legacy in sneakers.The air jordan retro 11 are the most famous and most popular model of the Air Jordan line.The Air Jordan shoes 13 (XIII)¡¯s featured a nice hologram on the ankle and the design was inspired by a panther.The air jordan 23 (XV) was released in 1999/2000.cheap jordan shoes Jordans 16 is the first shoe after Michael¡¯s retirement. The design of the Jordan shoes 17 originated from the air craft X-15 The air jordan 10 was released in 2002. Jordans 18 were equipped with a gaiter/shroud that was removable and that would cover almost more than half of the shoe, Air Jordans 19 were no worse. 无标题文档

Name: Din Rail series
Type:
DRS-202M


 
DRS-202M
 
DRS-202M Single phase Din Rail Multi-tariff Meter with Modbus
 
protocol
 
 
Description
 
1. CI.1 accuracy(EN50470-1,EN50470-3).
2. 4 DIN module.
3. 35mm standard DIN rail installation
4. 100A Direct Current
5.  Include 1,2 and 4 tariffs meters options.
6.  RS-485 and far infrared port for communication.
7.  Communication protocol: MODBUS RTU
8.  Two current channel meters option.
9.  Display electrical units: Voltage (V),current(A),frequency(Hz),Energy(kWh)
 
Specifications:
Nominal voltage       (Un)                             230V AC
Operational voltage                                     161 - 300V AC
Insulation capabilities:    
AC voltage withstand                                   4KV for 1 minute     
Impulse voltage withstand                             6KV 1.2µS waveform
Current(A)
    Imin                                                       0.5
    Itr                                                          1.0
    Iref(Ib)                                                   10   
    Imax                                                      100
    Ist                                                         40mA          
Operational frequency range                       ±5%                    
Power consumption at 230VAC and 5A        1VA              
Test output flash rate (RED LED)           
    Test model:                                             1000imp/kWh
    Normal model:                                        10,1,0.1,0.01kWh/pulse options
Pulse output rate (pins 20 & 21)            
   Test model:                                             1000imp/kWh
   Normal model:                                         10,1,0.1,0.01kWh/pulse options