GIS mapping softeware GIS GIS mapping mapping softeware GIS softeware this is new replica watches website,We offer our customers swiss replica watches Rolex watches is designed to be solemn, practical,BMR not showy style was by a large number of people love.CHOPARD150 years since, OMEGA Swiss Omega watches put it firmly in the vanguard of the world watch industry location,PRADA BVLGARIremarkable achievements lay.you can but many DEWITT GUCCI HERMES PIAGET watches.replica watchesreplica best watches this is new jordan shoes air jordan shoes website.The Air Jordan 1 was released in 1985 kicking off not only the greatest legacy in sneakers.The air jordan retro 11 are the most famous and most popular model of the Air Jordan line.The Air Jordan shoes 13 (XIII)¡¯s featured a nice hologram on the ankle and the design was inspired by a panther.The air jordan 23 (XV) was released in 1999/2000.cheap jordan shoes Jordans 16 is the first shoe after Michael¡¯s retirement. The design of the Jordan shoes 17 originated from the air craft X-15 The air jordan 10 was released in 2002. Jordans 18 were equipped with a gaiter/shroud that was removable and that would cover almost more than half of the shoe, Air Jordans 19 were no worse. 无标题文档

Name: Din Rail series
Type:
DRT-301C M-bus


DRT-301C  M-BUS 
 
 
DRT-301C three phases four wires Din Rail Energy meter with M-bus protocol
 
 

Description:

1. Measuring of Active energy, accuracy class B&A (CI.1& 2)

2. 7 DIN module.

3. 35mm standard DIN rail installation

4. Direct metering up to 100A

5.  5A CT version for measuring with current transformers available

6. 27 CT Changing-Ratios to choose

7. M-bus interface built-in

8. Communication baud rate can be set 300,2400,9600

9.  The protocol is based on international standard EN13757-3:2004, EN1434-3:2007

Specifications:

Nominal voltage     (Un)                     230/400V AC (3~)
Operational voltage                          161/279  300/520V AC (3~)
Insulation capabilities:              
    - AC voltage withstand                 4KV for 1 minute      
     - Impulse voltage withstand           4KV -1.2µS waveform
Base current (Ib):
       CT type                                   1.5A
       Directly connect                       10A
Maximum rated current (Imax)     
      CT type                                    6A
      Directly connect                      100A                                 
Frequency(Hz)                                50/60
Internal power consumption               2W /10VA     per phase
Test output flash rate (PULSE LED)            
         CT type                                 1600imp/kWh
         Directly connect                     400imp/kWh
Test pulse output rate (pins 8 & 9)    
         CT type                                1600imp/kWh
         Directly connect                     400imp/kWh
CT Changing-Ratio                        27 ratios to choose
Data communication port               M-bus
Communication baud rate             300,2400,9600
M-bus downlink signal                   Master to slave,Voltage modulation
M-bus uplink signal                       slave to master,Current modulation